Operation Of Synchronous Motor At Constant Load Variable Excitation

We have seen previously that when load changes, for constant excitation, current drawn by the motor increases. But if excitation i.e. field current is changed keeping load constant, the synchronous motor reacts by by changing its power factor of operation. This is most interesting feature of synchronous motor. Let us see the details of such operation.

Consider a synchronous motor operating at a certain load. The corresponding load angle is ?.

At start, consider normal behaviour of the synchronous motor, where excitation is adjusted to get E= V i.e. induced e.m.f. is equal to applied voltage. Such an excitation is called Normal Excitation of the motor. Motor is drawing certain current from the supply and power input to the motor is say  Pin. The power factor of the motor is lagging in nature as shown in the Fig. 1(a).

Now when excitation is changed, changes but there is hardly any change in the losses of the motor. So the power input also remains same for constant load demanding same power output.

Now            Pin = ?3 VIcos ? = 3 (Vph Iph cos ?)

Most of the times, the voltage applied to the motor is constant. Hence for constant power input as Vph is constant, ‘Iph cos ?’ remains constant.

Note : So far this entire operation of variable excitation it is necessary to remember that the cosine component of armature current, Icos? remains constant.

So motor adjusts its cos ? i.e. p.f. nature and value so that Icos ? remains constant when excitation of the motor is changed keeping load constant. This is the reason why synchronous motor reacts by changing its power factor to variable excitation conditions.

1.1 Under Excitation

When the excitation is adjusted in such a way that the magnitude of induced e.m.f. is less than the applied voltage (E< V) the excitation is called Under Excitation. Due to this, Eincreases in magnitude. This means for constant Zs, current drawn by the motor increases. But Ephase shifts in such a way that, phasor Ialso shifts (as ER  ^ I= ?) to keep Icos ? component constant. This is shown in the Fig. 1(b). So in under excited condition, current drawn by the motor increases. The p.f. cos ? decreases and becomes more and more lagging in nature.

1.2 Over Excitation 

The excitation to the field winding for which the induced e.m.f. becomes greater than applied voltage (E< V), is called over excitation. Due to increased magnitude of Eb, Ealso increases in magnitude. But the phase of  Ealso changes. Now = ER  ^ I= ?is constant, hence  Ialso changes its phase. So ? changes. The Iincreases to keep Icos ? constant as shown in Fig.1(c). The phase of Echanges so that Ibecomes leading with respect to  Vph  in over excited condition. So power factor of the motor becomes leading in nature. So overexcited synchronous motor works on leading power factor. So power factor decreases as over excitation increases but it becomes more and more leading in nature.

1.3 Critical Excitation

When the excitation is changed, the power factor changes. The excitation for which the power factor of the motor is unity (cos ? = 1) is called critical excitation. Then  Iaph is in phase with Vph. Now Icos ? must be constant, cos ? = 1 is at its maximum hence motor has to draw minimum current from supply for unity power factor condition.

So for critical excitation, cos ? = 1 and current drawn by the motor is minimum compared to current drawn by the motor for various excitation conditions. This is shown in the Fig. 1(d).

Fig. 1 Constant load variable excitation operation
admin

Share
Published by
admin

Recent Posts

Standby Generators and Custom Commercial Generators for Sale

Humankind has become extremely dependent on electricity, without it we can’t run the household, keep…

4 years ago

Electrical Machine Interview Question And Answer

[1] Define the term synchronous speed [Dec-2003] For synchronous machines there exists a fixed relationship…

7 years ago

Transformer Interview Questions With Answer

We shared a lot of interview questions on electrical machines, power system and power electronics. Today we…

7 years ago

What Is Diesel Power Station

DIESEL POWER STATION A generating station in which diesel engine is used as the prime…

7 years ago

Synchronous Generator Interview Questions

Q:Why syn. generators are used for the production of electricity? A:synchronous machines have capability to…

7 years ago

Hydro Power Station

Hydro-electric Power Station A generating station which utilises the potential energy of water at a…

7 years ago